Baisse de prix Gauss
Astec chiraldex b-ph gc column 30 m 0,25 mm
Réf.
UGAP : 2662601
Réf.
Fournisseur : 71023AST
Réf.
Constructeur : 71023AST
Franco de port et d'emballage pour toutes les commandes supérieures à 80€ HT.
Points clés
CD Type: β (beta)
Derivative: S-Hydroxypropyl
Temp. Limits: -10 °C to 200 °C (isothermal) or 220 °C (programmed)
Incorporates a phase consisting of a (S)-2-hydroxy propyl methyl ether derivative of β-cyclodextrin. This phase separates a wide variety of enantiomers, resolving aliphatic, olefinic, and aromatic enantiomers. It is a good general purpose chiral column.
The first general purpose derivative involved substitution of the cyclodextrin hydroxyl groups with pure "S" hydroxypropyl followed by permethylation. The surface is hydrophilic in character and the influence of size and shape selectivity is greatly reduced but not absent. The beta-cyclodextrin* form has the broadest applicability.
Features:
Hydrophilic surface
Beta is more selective than alpha
Separates a wide variety of enantiomers
Resolves aliphatic, olefinic and aromatic enantiomers
Good general purpose chiral column
Mechanism Observations:
Reduced influence of inclusion complexing
Less size selectivity for PH as opposed to DA
Temperature range for enantiomeric selectivity: Isothermal to 200°C; temperature program to 220°C
Characteristic temperature selectivity on a given column for a given class of compounds
Fewer functional requirements for analyte than LC
En savoir plusDerivative: S-Hydroxypropyl
Temp. Limits: -10 °C to 200 °C (isothermal) or 220 °C (programmed)
Incorporates a phase consisting of a (S)-2-hydroxy propyl methyl ether derivative of β-cyclodextrin. This phase separates a wide variety of enantiomers, resolving aliphatic, olefinic, and aromatic enantiomers. It is a good general purpose chiral column.
The first general purpose derivative involved substitution of the cyclodextrin hydroxyl groups with pure "S" hydroxypropyl followed by permethylation. The surface is hydrophilic in character and the influence of size and shape selectivity is greatly reduced but not absent. The beta-cyclodextrin* form has the broadest applicability.
Features:
Hydrophilic surface
Beta is more selective than alpha
Separates a wide variety of enantiomers
Resolves aliphatic, olefinic and aromatic enantiomers
Good general purpose chiral column
Mechanism Observations:
Reduced influence of inclusion complexing
Less size selectivity for PH as opposed to DA
Temperature range for enantiomeric selectivity: Isothermal to 200°C; temperature program to 220°C
Characteristic temperature selectivity on a given column for a given class of compounds
Fewer functional requirements for analyte than LC
Garantie
Garantie 0 Mois
Description
Astec(R) CHIRALDEX(R) B-PH Capillary GC Column,L x I.D. 30 m x 0.25 mm, df 0.12 mum
Caractéristiques
- Géométrie
- L x I.D.. 30 m x 0,25 mm
- Matière
- fused silica
- Délai de péremption
- 12
- Nomenclature IFPEN
- NB.21
- Nomenclature CNRS
- NB21
- Marque
- SUPELCO
- Fournisseur
- SIGMA ALDRICH CHIMIE
- Quantité
- 1
- Référence distributeur
- 71023AST
- Téléphone du titulaire
- 04.74.82.29.25
- Usage recommandé
- ANALYTICAL,GAS CHROMATOGRAPHY,CAPILLARY GC,CHIRAL,CHIRALDEX
- Lieu de stockage
- France
- Nomenclature CEA
- SHP16
- Libellé produit fabricant
- ASTEC CHIRALDEX B-PH GC COL 30 m 0.25 mM
- Libellé produit habituel
- ASTEC CHIRALDEX B-PH GC COL 30 m 0.25 mM
- Référence fabricant
- 71023AST
- Reprise en cas d’erreur client
- oui
- Nomenclature CHU
- 18.52.
- Nomenclature Nacres
- NB.21
- Nomenclature IRSN
- 189
- Nomenclature INSERM
- NB.NB21