Gauss

Seringue 901 rn 10 µl aiguille 26512 hamilton

Réf. UGAP : 2613784 Réf. Fournisseur : HAMI80370 Réf. Constructeur : 80370
Seringue 901 rn 10 µl aiguille 26512 hamilton
Livraison franco de port et d'emballage
La quantité choisie doit être comprise entre 1 et 999 999.
Il ne reste que 0 exemplaires.

Points clés

The 900 series syringe is the economical version of the 800 series syringe. This series of syringes is ideal for dispensing volumes from 0,5 µl up to 10 µl. The syringe holder is permanently attached to the syringe barrel. This reduces the initial cost of the syringe but eliminates the possibility of replacement components.
Syringe terminations:
N, Cemented Needle
For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable.
RN, Removable Needle
The needles are removable and are a Hamilton specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length and point style to optimise the syringe for custom applications. Additionally, this termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life.
Needle point styles:
Point Style 2
Sharp, beveled, curved, non-coring needle point recommended for septum penetration.
Available gauges: 34 - 10.

Seringue, chromatographie, Microliter™, HPLC/GC, 901 RN, Volume: 10 µl, Type de pointe: 2, Jauge: 26s, Longueur: 51 mm, Ø ext.: 0,47 mm, Cdt: 1

En savoir plus

Garantie

Garantie 0 Mois

Description

The 900 series syringe is the economical version of the 800 series syringe. This series of syringes is ideal for dispensing volumes from 0,5 µl up to 10 µl. The syringe holder is permanently attached to the syringe barrel. This reduces the initial cost of the syringe but eliminates the possibility of replacement components.
Syringe terminations:
N, Cemented Needle
For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. With this termination, dead volume is limited to the internal volume of the needle. Not autoclavable. Needle gauge is determined by the syringe volume and are not user-selectable.
RN, Removable Needle
The needles are removable and are a Hamilton specific design. The design allows the needles to seat precisely at the zero graduation mark of the syringe. Users can select the needle gauge, length and point style to optimise the syringe for custom applications. Additionally, this termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging. Autoclavable when disassembled. Repeated autoclaving will shorten syringe life.
Needle point styles:
Point Style 2
Sharp, beveled, curved, non-coring needle point recommended for septum penetration.
Available gauges: 34 - 10.

Seringue, chromatographie, Microliter™, HPLC/GC, 901 RN, Volume: 10 µl, Type de pointe: 2, Jauge: 26s, Longueur: 51 mm, Ø ext.: 0,47 mm, Cdt: 1

Caractéristiques

Fournisseur
VWR INTERNATIONAL
Nomenclature INSERM
NB.NB21
Volume
10 µl
Nomenclature CNRS
NB21
Libellé produit fabricant
Seringue 901 rn 10 µl aiguille 26512 Hamilton
Référence distributeur
HAMI80370
Téléphone du titulaire
08.25.02.30.30
Nomenclature Nacres
NB.21
Lieu de stockage
Belgique
Reprise en cas d’erreur client
oui
Libellé produit habituel
Seringue 901rn 10ul ga26s 51 mm pt2
Référence fabricant
80370
Gamme
MICROLITER™
Longueur
51
Jauge
26s
Nomenclature IRSN
189
Quantité
1
Poids
0,053
Nomenclature CHU
18.52.
Type de produit
Seringue
Marque
HAMILTON
Lieu de fabrication
États-Unis
Usage recommandé
accessoire chromatographie
Nomenclature CEA
SHP16
Diamètre
0,47 mm