Points clés
SUPELCOGEL 8 Column Series (manufactured with 8% XL PS-DVB):
The majority of columns on the market for the analysis of carbohydrates, organic acids, and alcohols, such as Aminex®, utilize an 8% XL PS-DVB. The 8% polymer offers excellent separation of many common samples.
Advantages: 8% polymers combine durability and good resolution. Due to higher cross-linking than 6% XL polymers, columns packed with 8% polymer can be used at higher flow rates therefore decreasing analysis times.
Disadvantages: 8% polymers are limited in separating carbohydrates larger than trisaccharides due to lower MW exclusion limits. Compared to the 6% XL polymer, for some types of carbohydrate and organic acid mixtures, the 8% shows less resolution due to selectivity differences.
Molecular Weight Exclusion Limit: 1200
Minimum Wet Capacity meq/ml: 1.7 - 1.9
Flow Rate Recommendation: 0.4 - 1.2 ml/min
En savoir plusThe majority of columns on the market for the analysis of carbohydrates, organic acids, and alcohols, such as Aminex®, utilize an 8% XL PS-DVB. The 8% polymer offers excellent separation of many common samples.
Advantages: 8% polymers combine durability and good resolution. Due to higher cross-linking than 6% XL polymers, columns packed with 8% polymer can be used at higher flow rates therefore decreasing analysis times.
Disadvantages: 8% polymers are limited in separating carbohydrates larger than trisaccharides due to lower MW exclusion limits. Compared to the 6% XL polymer, for some types of carbohydrate and organic acid mixtures, the 8% shows less resolution due to selectivity differences.
Molecular Weight Exclusion Limit: 1200
Minimum Wet Capacity meq/ml: 1.7 - 1.9
Flow Rate Recommendation: 0.4 - 1.2 ml/min
Garantie
Garantie 0 Mois
Description
SUPELCOGEL(TM) 8H, 8% Crosslinked HPLC Column,9 mum particle size, L x I.D. 30 cm x 7.8 mm
Caractéristiques
- Géométrie
- L x I.D.. 30 cm x 7,8 mm
- Marque
- SUPELCO
- Délai de péremption
- 12
- Référence distributeur
- 59246-U
- Libellé produit fabricant
- SUPELCOGEL 8H 30 cM X 7.8 mM HPLC COLUMN &
- Lieu de stockage
- France
- Référence fabricant
- 59246-U
- Libellé produit habituel
- SUPELCOGEL 8H 30 cM X 7.8 mM HPLC COLUMN &
- Nomenclature CNRS
- NB21
- Téléphone du titulaire
- 04.74.82.29.25
- Nomenclature CEA
- SHP16
- Fournisseur
- SIGMA ALDRICH CHIMIE
- Usage recommandé
- ANALYTICAL,HPLC,SUPELCO COLUMNS,SUPELCOGEL,CARBOHYDRATES
- Reprise en cas d’erreur client
- oui
- Nomenclature CHU
- 18.52.
- Nomenclature Nacres
- NB.21
- Nomenclature INSERM
- NB.NB21
- Nomenclature IRSN
- 189
- Quantité
- 1