HTRF - Kinase-biotin binding discovery kit
Produit ni repris ni échangé excepté en cas d’erreur du prestataire.
Points clés
The best known kinase inhibitor, Gleevec (Imatinib), binds a non-activated form of Abl. Such inhibitors are therefore more difficult to detect using activity based assays, so it is worthwhile to set up kinase binding assays for your kinase of interest in order to avoid missing out on such compounds. Moreover the HTRF® kinase binding assays are easily set up, using a mix and measure detection format in the absence of ATP. Direct displacement of the fluorescent-inhibitor from the ATP binding pocket is measured, enabling the determination of the affinity of your inhibitor by performing dose response curves. Purified kinase preparation is less critical compared to enzymatic assays, since measurements can be performed on kinases which have little or no activity.
Garantie
Garantie 0 Mois
Description
The best known kinase inhibitor, Gleevec (Imatinib), binds a non-activated form of Abl. Such inhibitors are therefore more difficult to detect using activity based assays, so it is worthwhile to set up kinase binding assays for your kinase of interest in order to avoid missing out on such compounds. Moreover the HTRF® kinase binding assays are easily set up, using a mix and measure detection format in the absence of ATP. Direct displacement of the fluorescent-inhibitor from the ATP binding pocket is measured, enabling the determination of the affinity of your inhibitor by performing dose response curves. Purified kinase preparation is less critical compared to enzymatic assays, since measurements can be performed on kinases which have little or no activity.
Caractéristiques
- Marque
- REVVITY
- Libellé produit fabricant
- Kinase-biotin Binding Discovery Kit, 1 Unit
- Référence distributeur
- 62KBD03PEA
- Référence fabricant
- 62KBD03PEA
- Fournisseur
- REVVITY
- Reprise en cas d’erreur client
- non
- Lieu de fabrication
- France
- Lieu de stockage
- France
- Domaine de recherche
- biologie - biochimie - test d'activité enzymatique
- Délai de péremption à la date de livraison
- 6 mois
- Soumis à carboglace
- oui
- Soumis à réglementation
- non
- Température de conservation (°C)
- -30 à -16 °C
- Type d’application
- imagerie in-vivo
- Vendu par
- 1 kit
- Quantité
- N/A
- Nomenclature Nacres
- NA.84
- Nomenclature CEA
- SGP01
- Nomenclature IRSN
- 273
- Nomenclature INSERM
- NA.NA84
- Nomenclature CNRS
- NA84
- Nomenclature CHU
- 18.551
- Nomenclature DGOS
- LD11AOOO