Gauss

Kit de quantification viabilite cellulules spheroides atplite 3d 300 tests

Réf. UGAP : 3731426 Réf. Fournisseur : 6066943 Réf. Constructeur : 6066943
Kit de quantification viabilite cellulules spheroides atplite 3d 300 tests
Franco de port et d'emballage pour toutes les commandes supérieures à 80€ HT.

Produit ni repris ni échangé excepté en cas d’erreur du prestataire.
La quantité choisie doit être comprise entre 1 et 999 999.

Points clés

Simple, rapide, sensible, non toxique, livré à température ambiante

ATP is a marker for cell viability because it is present in all metabolically active cells. Because ATP concentration declines rapidly when cells undergo necrosis or apoptosis, monitoring ATP is a good indicator of cytocidal, cytostatic and proliferation effects. Our ATPlite 3D and ATPlite 1step 3D luminescence assay systems use patented innovative technologies that measure cell proliferation and cytotoxicity in 3D cultured mammalian cells based on the production of light caused by the reaction of ATP with added luciferase and D-luciferin. ATPlite™ 3D is an Adenosine TriPhosphate (ATP) monitoring system based on firefly (Photinus pyralis) luciferase. This luminescence assay is the alternative to colorimetric, fluorometric, high content microscopic analysis and radioisotopic assays for the quantitative evaluation of proliferation and cytotoxicity of mammalian cells cultured in 3D spheroids. ATP monitoring can be used to assess the cytocidal, cytostatic and proliferative effects of a wide range of drugs, biological response modifiers and biological compounds. Advantages: Long-lived luminescent signal: half-life (t1/2) greater than 5 hours, depending on cell type and medium The separate lysis step, using sodium hydroxide for tissue lysis, is the best option for full spheroid lysis and extraction of ATP Rapid: results generated in 40 - 45 minutes Simple and reproducible: no separation steps; only two reagent additions and mixing. A final transfer step may be necessary, depending on the type of plate used for Spheroid growth Homogeneous assay: no cell harvesting or centrifugation required Wide linear dynamic range: detect ATP from spheroids made by seeding as few as 200 cells, and up to 5000 cells Convenient storage conditions (2 - 8 °C) No DTT: Unlike most luciferase detection reagents, lites products do not contain DTT, eliminating toxic hazards, unpleasant odors and the need for hood work Excellent Z' Values: All lites products offer robust, sensitive performance, with high signal-to-background ratios and excellent Z'values Kit Components 3 vials of Lyophilized Substrate Solution 1 x 20 mL of Substrate Buffer Solution 1 x 20 mL of Mammalian Cell Lysis Solution (MCLS) 1 vial of Lyophilized ATP Standard Solution 1 x CellCarrier Spheroid ULA 96-well microplate (product # 6055330; 10 plates, 6055334; 40 plates) 1 x OptiPlate-96 (product# 60052900 for 50 plates; 6005299 for 200 plates) 4 x TopSeal-A (product # 6050185; 100 seals) 1 x Quick Start Guide Storage: Buffer, MCLS and vials should be stored at 4°C. Microplates and TopSeal-A can be stored at Room Temperature.

En savoir plus

Garantie

Garantie 0 Mois

Description

Simple, rapide, sensible, non toxique, livré à température ambiante

ATP is a marker for cell viability because it is present in all metabolically active cells. Because ATP concentration declines rapidly when cells undergo necrosis or apoptosis, monitoring ATP is a good indicator of cytocidal, cytostatic and proliferation effects. Our ATPlite 3D and ATPlite 1step 3D luminescence assay systems use patented innovative technologies that measure cell proliferation and cytotoxicity in 3D cultured mammalian cells based on the production of light caused by the reaction of ATP with added luciferase and D-luciferin. ATPlite™ 3D is an Adenosine TriPhosphate (ATP) monitoring system based on firefly (Photinus pyralis) luciferase. This luminescence assay is the alternative to colorimetric, fluorometric, high content microscopic analysis and radioisotopic assays for the quantitative evaluation of proliferation and cytotoxicity of mammalian cells cultured in 3D spheroids. ATP monitoring can be used to assess the cytocidal, cytostatic and proliferative effects of a wide range of drugs, biological response modifiers and biological compounds. Advantages: Long-lived luminescent signal: half-life (t1/2) greater than 5 hours, depending on cell type and medium The separate lysis step, using sodium hydroxide for tissue lysis, is the best option for full spheroid lysis and extraction of ATP Rapid: results generated in 40 - 45 minutes Simple and reproducible: no separation steps; only two reagent additions and mixing. A final transfer step may be necessary, depending on the type of plate used for Spheroid growth Homogeneous assay: no cell harvesting or centrifugation required Wide linear dynamic range: detect ATP from spheroids made by seeding as few as 200 cells, and up to 5000 cells Convenient storage conditions (2 - 8 °C) No DTT: Unlike most luciferase detection reagents, lites products do not contain DTT, eliminating toxic hazards, unpleasant odors and the need for hood work Excellent Z' Values: All lites products offer robust, sensitive performance, with high signal-to-background ratios and excellent Z'values Kit Components 3 vials of Lyophilized Substrate Solution 1 x 20 mL of Substrate Buffer Solution 1 x 20 mL of Mammalian Cell Lysis Solution (MCLS) 1 vial of Lyophilized ATP Standard Solution 1 x CellCarrier Spheroid ULA 96-well microplate (product # 6055330; 10 plates, 6055334; 40 plates) 1 x OptiPlate-96 (product# 60052900 for 50 plates; 6005299 for 200 plates) 4 x TopSeal-A (product # 6050185; 100 seals) 1 x Quick Start Guide Storage: Buffer, MCLS and vials should be stored at 4°C. Microplates and TopSeal-A can be stored at Room Temperature.

Caractéristiques

Marque
REVVITY
Libellé produit fabricant
ATP LITE 3D, 300 ASSAY KIT
Référence distributeur
6066943
Référence fabricant
6066943
Fournisseur
REVVITY
Reprise en cas d’erreur client
non
Lieu de fabrication
Pays-bas
Lieu de stockage
Pays-bas
Domaine de recherche
biologie cellulaire
Délai de péremption à la date de livraison
6 mois
Soumis à carboglace
non
Soumis à réglementation
non
Type d’application
viabilité cellulaire
Vendu par
300 tests
Quantité
N/A
Nomenclature IFPEN
NA.84
Nomenclature Nacres
NA.84
Nomenclature CEA
SGP01
Nomenclature IRSN
273
Nomenclature INSERM
NA.NA84
Nomenclature CNRS
NA84
Nomenclature CHU
18.551
Nomenclature DGOS
LD11AOOO
Certification
RUO
Type d'échantillon
culture cellulaire