Kit quantification viabilite atplite perkinelmer 10000 tests
Produit ni repris ni échangé excepté en cas d’erreur du prestataire.
Points clés
ATP is a marker for cell viability because it is present in all metabolically active cells. Because ATP concentration declines rapidly when cells undergo necrosis or apoptosis, monitoring ATP is a good indicator of cytocidal, cytostatic and proliferation effects. Our ATPlite and ATPlite 1step luminescence assay systems use patented innovative technologies that measure cell proliferation and cytotoxicity in mammalian cells based on the production of light caused by the reaction of ATP with added luciferase and D-luciferin. ATPlite™ is an Adenosine TriPhosphate (ATP) monitoring system based on firefly (Photinus pyralis) luciferase. This luminescence assay is the alternative to colorimetric, fluorometric and radioisotopic assays for the quantitative evaluation of proliferation and cytotoxicity of cultured mammalian cells. ATP monitoring can be used to assess the cytocidal, cytostatic and proliferative effects of a wide range of drugs, biological response modifiers and biological compounds. Advantages: Long-lived luminescent signal: half-life (t1/2) greater than 5 hours, depending on cell type and medium Rapid: results generated in 15 - 25 minutes Simple and reproducible: no separation steps; only two reagent additions Homogeneous assay: no cell harvesting or centrifugation required Sensitive: down to 5 cells in 100µL medium (derived from CHO and HL-60 cells in 100µL medium) Wide linear dynamic range: 105 (as derived from CHO and HL-60 cells)
Garantie
Garantie 0 Mois
Description
ATP is a marker for cell viability because it is present in all metabolically active cells. Because ATP concentration declines rapidly when cells undergo necrosis or apoptosis, monitoring ATP is a good indicator of cytocidal, cytostatic and proliferation effects. Our ATPlite and ATPlite 1step luminescence assay systems use patented innovative technologies that measure cell proliferation and cytotoxicity in mammalian cells based on the production of light caused by the reaction of ATP with added luciferase and D-luciferin. ATPlite™ is an Adenosine TriPhosphate (ATP) monitoring system based on firefly (Photinus pyralis) luciferase. This luminescence assay is the alternative to colorimetric, fluorometric and radioisotopic assays for the quantitative evaluation of proliferation and cytotoxicity of cultured mammalian cells. ATP monitoring can be used to assess the cytocidal, cytostatic and proliferative effects of a wide range of drugs, biological response modifiers and biological compounds. Advantages: Long-lived luminescent signal: half-life (t1/2) greater than 5 hours, depending on cell type and medium Rapid: results generated in 15 - 25 minutes Simple and reproducible: no separation steps; only two reagent additions Homogeneous assay: no cell harvesting or centrifugation required Sensitive: down to 5 cells in 100µL medium (derived from CHO and HL-60 cells in 100µL medium) Wide linear dynamic range: 105 (as derived from CHO and HL-60 cells)
Caractéristiques
- Marque
- REVVITY
- Libellé produit fabricant
- ATP LITE 10.000 ASSAY KIT
- Référence distributeur
- 6016949
- Référence fabricant
- 6016949
- Fournisseur
- REVVITY
- Reprise en cas d’erreur client
- non
- Lieu de fabrication
- Pays-bas
- Lieu de stockage
- Pays-bas
- Domaine de recherche
- biologie cellulaire
- Délai de péremption à la date de livraison
- 6 mois
- Soumis à carboglace
- non
- Soumis à réglementation
- non
- Type d’application
- viabilité - ATP - luciférase
- Vendu par
- 10000 tests
- Quantité
- N/A
- Nomenclature Nacres
- NA.84
- Nomenclature CEA
- SGP01
- Nomenclature IRSN
- 273
- Nomenclature INSERM
- NA.NA84
- Nomenclature CNRS
- NA84
- Nomenclature CHU
- 18.551
- Nomenclature DGOS
- LD11AOOO