Points clés

Accurately determining gastric emptying rates is crucial for understanding the physiological mechanisms underlying alterations in gastric motility. Additionally, a pharmacological agent’s effects on gastric emptying can determine its potential as a therapeutic. Currently, the methods used for preclinical determination of gastric emptying rates involve terminal assessment of dye or radioactive tracers within the stomach. These methods require the use of many animals, incurring high financial and time costs. IVISense Gastrointestinal 750 fluorescent probe enables non-invasive in vivo visualization and quantification of the effects of disease or drugs on the GI tract. Tips: IVISense Gastrointestinal 750 fluoresscent probe may also be administered as part of a solid diet by applying the reconstituted solution to egg yolk. When added to a solid diet it may be easier to reconstitute the vial of the probe with 300 µL of 1x PBS and use 25 µL per mouse. IVISense Gastrointestinal fluorescent agent remains localized in the GI tract and is not absorbed into the bloodstream.

En savoir plus

Garantie

Garantie 0 Mois

Description

Accurately determining gastric emptying rates is crucial for understanding the physiological mechanisms underlying alterations in gastric motility. Additionally, a pharmacological agent’s effects on gastric emptying can determine its potential as a therapeutic. Currently, the methods used for preclinical determination of gastric emptying rates involve terminal assessment of dye or radioactive tracers within the stomach. These methods require the use of many animals, incurring high financial and time costs. IVISense Gastrointestinal 750 fluorescent probe enables non-invasive in vivo visualization and quantification of the effects of disease or drugs on the GI tract. Tips: IVISense Gastrointestinal 750 fluoresscent probe may also be administered as part of a solid diet by applying the reconstituted solution to egg yolk. When added to a solid diet it may be easier to reconstitute the vial of the probe with 300 µL of 1x PBS and use 25 µL per mouse. IVISense Gastrointestinal fluorescent agent remains localized in the GI tract and is not absorbed into the bloodstream.

Caractéristiques

Marque
REVVITY
Libellé produit fabricant
IVISense Gastrointestinal 750 Fluorescent Probe (GastroSense)
Référence distributeur
NEV11121
Référence fabricant
NEV11121
Fournisseur
REVVITY
Reprise en cas d’erreur client
non
Lieu de fabrication
États-Unis
Lieu de stockage
États-Unis
Domaine de recherche
biologie cellulaire
Délai de péremption à la date de livraison
12 mois
Soumis à carboglace
non
Soumis à réglementation
non
Température de conservation (°C)
+2 à +8 °C
Type d’application
imagerie
Vendu par
1 pcs
Quantité
N/A
Nomenclature IFPEN
NA.83
Nomenclature Nacres
NA.83
Nomenclature CEA
SGP01
Nomenclature IRSN
273
Nomenclature INSERM
NA.NA83
Nomenclature CNRS
NA83
Nomenclature CHU
18.551
Nomenclature DGOS
LD11AOOO
Type d'échantillon
sérum, plasma, surnageant de culture cellulaire, tissu
Certification
RUO