Gauss

Réactifs pour l'analyse d'ADN 12K 1 Kit

Réf. UGAP : 3731281 Réf. Fournisseur : 760569 Réf. Constructeur : 760569
Réactifs pour l'analyse d'ADN 12K 1 Kit
Franco de port et d'emballage pour toutes les commandes supérieures à 80€ HT.

Produit ni repris ni échangé excepté en cas d’erreur du prestataire.
La quantité choisie doit être comprise entre 1 et 999 999.
Il ne reste que 0 exemplaires.

Points clés

Performing DNA sample analysis with the DNA 12K assay saves time and money by automating steps for analyzing size and purity, and replaces agarose slab gels, and imaging. The LabChip® GX and GX Touch Electrophoresis Systems uses a single sipper microfluidic chip to aspirate dsDNA samples directly from 96- or 384-well plates. The microfluidics chip technology automatically mixes in an intercolating dye, electrophoretically separates, and analyzes the DNA sample. The instrument optics detect the laser-induced fluorescent signal. System software automatically analyzes the data and determines fragment size and concentration using ladder and marker calibration standards. Digital data results are immediately available for review or reporting in virtual gel, electropherogram graph, or table summary form. Chip and Reagents sold separately: DNA Extended Range Chip (P/N 760517, LabChip GX, LabChip GX Touch HT P/N CLS 138948, LabChip GX Touch 24 ) DNA 12K Reagent (P/N 760569) Additional Specifications Sizing Range - 100 bp – 12000 bp Sizing Accuracy - ± 10% Sizing Resolution - ± 10% from 150 – 1000 bp ± 15% from 1000 – 2000 bp ± 20% from 2000 – 8000 bp ± 25% from 100 – 150 bp, 8000 – 12000 bp Linear Concentration Range – 0.25 ng/µL – 50 ng / µL Per fragment Sensitivity – 0.25 ng / µL Chip Sample Lifetime – 2000

En savoir plus

Garantie

Garantie 0 Mois

Description

Performing DNA sample analysis with the DNA 12K assay saves time and money by automating steps for analyzing size and purity, and replaces agarose slab gels, and imaging. The LabChip® GX and GX Touch Electrophoresis Systems uses a single sipper microfluidic chip to aspirate dsDNA samples directly from 96- or 384-well plates. The microfluidics chip technology automatically mixes in an intercolating dye, electrophoretically separates, and analyzes the DNA sample. The instrument optics detect the laser-induced fluorescent signal. System software automatically analyzes the data and determines fragment size and concentration using ladder and marker calibration standards. Digital data results are immediately available for review or reporting in virtual gel, electropherogram graph, or table summary form. Chip and Reagents sold separately: DNA Extended Range Chip (P/N 760517, LabChip GX, LabChip GX Touch HT P/N CLS 138948, LabChip GX Touch 24 ) DNA 12K Reagent (P/N 760569) Additional Specifications Sizing Range - 100 bp – 12000 bp Sizing Accuracy - ± 10% Sizing Resolution - ± 10% from 150 – 1000 bp ± 15% from 1000 – 2000 bp ± 20% from 2000 – 8000 bp ± 25% from 100 – 150 bp, 8000 – 12000 bp Linear Concentration Range – 0.25 ng/µL – 50 ng / µL Per fragment Sensitivity – 0.25 ng / µL Chip Sample Lifetime – 2000

Caractéristiques

Produit captif
oui
Marque
REVVITY
Libellé produit fabricant
DNA 12K Reagent Kit
Référence distributeur
760569
Référence fabricant
760569
Fournisseur
REVVITY
Reprise en cas d’erreur client
non
Lieu de fabrication
États-Unis
Lieu de stockage
États-Unis
Domaine de recherche
réactifs et kits pour le marquage et la detection des acides nucléiques
Délai de péremption à la date de livraison
2 à 4 mois
Soumis à carboglace
oui
Soumis à réglementation
non
Type d’application
dépistage prénatal
Vendu par
1 kit
Quantité
N/A
Nomenclature Nacres
NA.31
Nomenclature CEA
SGP01
Nomenclature IRSN
273
Nomenclature INSERM
NA.NA31
Nomenclature CNRS
NA31
Nomenclature CHU
18.551
Nomenclature DGOS
LD10AOOO

Fournisseur