Réactifs pour l'analyse d'ADN 12K 1 Kit
Produit ni repris ni échangé excepté en cas d’erreur du prestataire.
Points clés
Performing DNA sample analysis with the DNA 12K assay saves time and money by automating steps for analyzing size and purity, and replaces agarose slab gels, and imaging. The LabChip® GX and GX Touch Electrophoresis Systems uses a single sipper microfluidic chip to aspirate dsDNA samples directly from 96- or 384-well plates. The microfluidics chip technology automatically mixes in an intercolating dye, electrophoretically separates, and analyzes the DNA sample. The instrument optics detect the laser-induced fluorescent signal. System software automatically analyzes the data and determines fragment size and concentration using ladder and marker calibration standards. Digital data results are immediately available for review or reporting in virtual gel, electropherogram graph, or table summary form. Chip and Reagents sold separately: DNA Extended Range Chip (P/N 760517, LabChip GX, LabChip GX Touch HT P/N CLS 138948, LabChip GX Touch 24 ) DNA 12K Reagent (P/N 760569) Additional Specifications Sizing Range - 100 bp – 12000 bp Sizing Accuracy - ± 10% Sizing Resolution - ± 10% from 150 – 1000 bp ± 15% from 1000 – 2000 bp ± 20% from 2000 – 8000 bp ± 25% from 100 – 150 bp, 8000 – 12000 bp Linear Concentration Range – 0.25 ng/µL – 50 ng / µL Per fragment Sensitivity – 0.25 ng / µL Chip Sample Lifetime – 2000
Garantie
Garantie 0 Mois
Description
Performing DNA sample analysis with the DNA 12K assay saves time and money by automating steps for analyzing size and purity, and replaces agarose slab gels, and imaging. The LabChip® GX and GX Touch Electrophoresis Systems uses a single sipper microfluidic chip to aspirate dsDNA samples directly from 96- or 384-well plates. The microfluidics chip technology automatically mixes in an intercolating dye, electrophoretically separates, and analyzes the DNA sample. The instrument optics detect the laser-induced fluorescent signal. System software automatically analyzes the data and determines fragment size and concentration using ladder and marker calibration standards. Digital data results are immediately available for review or reporting in virtual gel, electropherogram graph, or table summary form. Chip and Reagents sold separately: DNA Extended Range Chip (P/N 760517, LabChip GX, LabChip GX Touch HT P/N CLS 138948, LabChip GX Touch 24 ) DNA 12K Reagent (P/N 760569) Additional Specifications Sizing Range - 100 bp – 12000 bp Sizing Accuracy - ± 10% Sizing Resolution - ± 10% from 150 – 1000 bp ± 15% from 1000 – 2000 bp ± 20% from 2000 – 8000 bp ± 25% from 100 – 150 bp, 8000 – 12000 bp Linear Concentration Range – 0.25 ng/µL – 50 ng / µL Per fragment Sensitivity – 0.25 ng / µL Chip Sample Lifetime – 2000
Caractéristiques
- Produit captif
- oui
- Marque
- REVVITY
- Libellé produit fabricant
- DNA 12K Reagent Kit
- Référence distributeur
- 760569
- Référence fabricant
- 760569
- Fournisseur
- REVVITY
- Reprise en cas d’erreur client
- non
- Lieu de fabrication
- États-Unis
- Lieu de stockage
- États-Unis
- Domaine de recherche
- réactifs et kits pour le marquage et la detection des acides nucléiques
- Délai de péremption à la date de livraison
- 2 à 4 mois
- Soumis à carboglace
- oui
- Soumis à réglementation
- non
- Type d’application
- dépistage prénatal
- Vendu par
- 1 kit
- Quantité
- N/A
- Nomenclature Nacres
- NA.31
- Nomenclature CEA
- SGP01
- Nomenclature IRSN
- 273
- Nomenclature INSERM
- NA.NA31
- Nomenclature CNRS
- NA31
- Nomenclature CHU
- 18.551
- Nomenclature DGOS
- LD10AOOO