Extraction/Purification d'acides nucléiques GenElute -E Organic Solvent DNA Cleanup Kit, x250 réactions
Produit ni repris ni échangé excepté en cas d’erreur du prestataire.
Points clés
Fast and efficient purification (less than 3 minutes): single-spin protocol reduces pipetting steps and hands-on timeHigher quality DNA: negative chromotography-based purification reduces carryover of PCR inhibitors and other contaminents Reduced environmental impact: 55% less plastic waste, as well as a significant reduction in hazardous chemicals
We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product is aligned with Waste prevention and Designing safer chemicals. Click here for more information._x005F_x000D_
DNA/RNA preparation by traditional methods frequently contains residual phenol and/or chloroform. The GenElute™-E Organic Solvent DNA Cleanup Kit is a one-step cleanup kit for the depletion of organic solvent traces, including phenol, TRIzol reagent, chloroform, and ethanol, from DNA solutions. Ideally suited for a reliable clean-up when a universal preparation for NGS library prep is desired or required._x005F_x000D_
_x005F_x000D_
GenElute™-E kits are based on the principle of negative chromatography, where impurities like salt, detergent, proteins and organic solvents are removed by the column material and the purified nucleic acid is collected in the flow-through in just one single centrifugation step. This convenient procedure enables a significantly faster purification of nucleic acid samples than standard bind-wash-elute procedures, with less handling, drastically reduced plastic consumable usage, and no use of hazardous materials like chaotropic salts or organic solvents._x005F_x000D_
_x005F_x000D_
With conventional methods, traces of chaotropic salt and ethanol are usually coeluted with these purification procedures, which often leads to inhibition of real-time PCR experiments. GenElute™-E kits do not contain any chaotropic salts, organic solvents or EDTA, resulting in improved performance in downstream applications such as PCR._x005F_x000D_
_x005F_x000D_
Because of the negative chromatography principle, there is no limitation to the amount of DNA that is cleaned up. Maximum sample volume is 100 μl. The purified nucleic acid is eluted in water and can immediately be used for downstream applications. A 1x TE Buffer, pH 8.5, is supplied to enable storage of samples. Produit à destination de la recherche uniquement
Garantie
Garantie 0 Mois
Description
Fast and efficient purification (less than 3 minutes): single-spin protocol reduces pipetting steps and hands-on timeHigher quality DNA: negative chromotography-based purification reduces carryover of PCR inhibitors and other contaminents Reduced environmental impact: 55% less plastic waste, as well as a significant reduction in hazardous chemicals
We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product is aligned with Waste prevention and Designing safer chemicals. Click here for more information._x005F_x000D_
DNA/RNA preparation by traditional methods frequently contains residual phenol and/or chloroform. The GenElute™-E Organic Solvent DNA Cleanup Kit is a one-step cleanup kit for the depletion of organic solvent traces, including phenol, TRIzol reagent, chloroform, and ethanol, from DNA solutions. Ideally suited for a reliable clean-up when a universal preparation for NGS library prep is desired or required._x005F_x000D_
_x005F_x000D_
GenElute™-E kits are based on the principle of negative chromatography, where impurities like salt, detergent, proteins and organic solvents are removed by the column material and the purified nucleic acid is collected in the flow-through in just one single centrifugation step. This convenient procedure enables a significantly faster purification of nucleic acid samples than standard bind-wash-elute procedures, with less handling, drastically reduced plastic consumable usage, and no use of hazardous materials like chaotropic salts or organic solvents._x005F_x000D_
_x005F_x000D_
With conventional methods, traces of chaotropic salt and ethanol are usually coeluted with these purification procedures, which often leads to inhibition of real-time PCR experiments. GenElute™-E kits do not contain any chaotropic salts, organic solvents or EDTA, resulting in improved performance in downstream applications such as PCR._x005F_x000D_
_x005F_x000D_
Because of the negative chromatography principle, there is no limitation to the amount of DNA that is cleaned up. Maximum sample volume is 100 μl. The purified nucleic acid is eluted in water and can immediately be used for downstream applications. A 1x TE Buffer, pH 8.5, is supplied to enable storage of samples. Produit à destination de la recherche uniquement
Caractéristiques
- Code à barre
- oui
- Marque
- SIGMA-ALDRICH
- Référence fabricant
- EC700-250RXN
- Référence distributeur
- EC700-250RXN
- Délai de péremption à la date de livraison
- 12 mois
- Fournisseur
- SIGMA ALDRICH CHIMIE
- Soumis à carboglace
- non
- Température de conservation (°C)
- ambiante °C
- Vendu par
- 250 réactions
- Nomenclature Nacres
- NA.31
- Nomenclature CEA
- SGP01
- Nomenclature IRSN
- 273
- Nomenclature INSERM
- NA.NA31
- Nomenclature CNRS
- NA31
- Nomenclature CHU
- 18.551
- Nomenclature DGOS
- LD10AOOO
- Reprise en cas d’erreur client
- non
- Lieu de stockage
- France
- Lieu de fabrication
- États-Unis
- Quantité
- N/A