Ampflstr identifiler plus pcr amplification kit-200 réactions
Produit ni repris ni échangé excepté en cas d’erreur du prestataire.
Points clés
200 reactions-optimized for casework, the ampflstr identifiler plus pcr amplification kit enables forensic analysts to recover more interpretable results from a wider range of dna evidence samples with increased confidence. the new kit includes the same primers and allelic ladder as the widely used identifiler kit and harnesses next-generation pcr amplification technology to help provide enhanced sensitivity, a cleaner baseline, improved performance on mixtures, and the ability to overcome high levels of pcr inhibition.features of the ampflstr identifiler plus pcr amplification kit include: amplifies the same loci as the identifiler kit with enhanced performance, data quality, and efficiency for casework samples helps significantly improve performance on severely inhibited casework samples through the use of a high performance pcr buffer system and optimized thermal cycling parameters yields higher peak heights from low-level samples and minor contributors in mixtures to facilitate interpretation enables additional analytical flexibility by utilizing fully-validated 28- and 29-cycle protocols streamlines workflow by enabling reduced amplification time maintains the small amplicon size range of the identifiler kit (other improvements and benefitsthe improvements in the identifiler plus kit formulation allow for more rapid amplification, eliminating approximately 1 hour from the amplification step compared to the identifiler kit. in addition, the identifiler plus master mix includes amplitaq gold dna polymerase, which eliminates 2 tubes and an extra box from the kit packaging, and enables streamlined reaction setup.none of the formulation enhancements included in the identifiler plus kit have required modifications to the identifiler kit’s allelic ladder or 5-dye configuration. this configuration allows for optimal locus spacing and amplicon size ranges no greater than 360 bp, enabling better data recovery from degraded samples as compared to other multiplex systems with significantly larger amplicon size ranges. for heavily degraded samples, the minifiler kit has been designed to work in conjunction with the identifiler plus kit, utilizing ministr technology to help maximize recovery of information.the identifiler plus kit also maintains primer sequences to enable genotyping concordance for samples previously typed using the identifiler, identifiler direct, profiler plus, cofiler or sgm plus kits, and facilitate comparison with existing dna databases.the confidence to do morethe identifiler plus kit is part of a new generation of ampflstr kits that harnesses significant advances in pcr amplification technology to enable recovery of more results from more samples with increased confidence.ultimately, laboratories using the identifiler plus kit could significantly increase their ability to process difficult and challenging casework samples, and expand the types of cases from which probative results can be generated.experience matterswe are the only company that designs and validates its reagents, instruments, and data analysis software together as an integrated system for dna testing. technical service scientists and field application specialists are available to answer your technical questions, review data, and make recommendations on how to perform assays and troubleshoot results. our team of forensic experts is also available to provide in-depth training and can support the planning and efficient execution of internal validation projects in your laboratory. all of these resources help ensure success when using our human identification solutions in your laboratory.for licensing and limited use restrictions visit thermofisher.com/hidlicensing.Delai de livraison moyen constaté : 24-48h
Garantie
Garantie 0 Mois
Description
200 reactions-optimized for casework, the ampflstr identifiler plus pcr amplification kit enables forensic analysts to recover more interpretable results from a wider range of dna evidence samples with increased confidence. the new kit includes the same primers and allelic ladder as the widely used identifiler kit and harnesses next-generation pcr amplification technology to help provide enhanced sensitivity, a cleaner baseline, improved performance on mixtures, and the ability to overcome high levels of pcr inhibition.features of the ampflstr identifiler plus pcr amplification kit include: amplifies the same loci as the identifiler kit with enhanced performance, data quality, and efficiency for casework samples helps significantly improve performance on severely inhibited casework samples through the use of a high performance pcr buffer system and optimized thermal cycling parameters yields higher peak heights from low-level samples and minor contributors in mixtures to facilitate interpretation enables additional analytical flexibility by utilizing fully-validated 28- and 29-cycle protocols streamlines workflow by enabling reduced amplification time maintains the small amplicon size range of the identifiler kit (other improvements and benefitsthe improvements in the identifiler plus kit formulation allow for more rapid amplification, eliminating approximately 1 hour from the amplification step compared to the identifiler kit. in addition, the identifiler plus master mix includes amplitaq gold dna polymerase, which eliminates 2 tubes and an extra box from the kit packaging, and enables streamlined reaction setup.none of the formulation enhancements included in the identifiler plus kit have required modifications to the identifiler kit’s allelic ladder or 5-dye configuration. this configuration allows for optimal locus spacing and amplicon size ranges no greater than 360 bp, enabling better data recovery from degraded samples as compared to other multiplex systems with significantly larger amplicon size ranges. for heavily degraded samples, the minifiler kit has been designed to work in conjunction with the identifiler plus kit, utilizing ministr technology to help maximize recovery of information.the identifiler plus kit also maintains primer sequences to enable genotyping concordance for samples previously typed using the identifiler, identifiler direct, profiler plus, cofiler or sgm plus kits, and facilitate comparison with existing dna databases.the confidence to do morethe identifiler plus kit is part of a new generation of ampflstr kits that harnesses significant advances in pcr amplification technology to enable recovery of more results from more samples with increased confidence.ultimately, laboratories using the identifiler plus kit could significantly increase their ability to process difficult and challenging casework samples, and expand the types of cases from which probative results can be generated.experience matterswe are the only company that designs and validates its reagents, instruments, and data analysis software together as an integrated system for dna testing. technical service scientists and field application specialists are available to answer your technical questions, review data, and make recommendations on how to perform assays and troubleshoot results. our team of forensic experts is also available to provide in-depth training and can support the planning and efficient execution of internal validation projects in your laboratory. all of these resources help ensure success when using our human identification solutions in your laboratory.for licensing and limited use restrictions visit thermofisher.com/hidlicensing.Delai de livraison moyen constaté : 24-48h
Caractéristiques
- Volume échantillon
- 25 µL µl
- Classement dans le catalogue fournisseur
- Kits and Assays/Forensic Testing Kits/Forensic DNA Identification Kits
- Marqueur
- FAM, LIZ, NED, PET, VIC
- Marquage CE DIV
- non
- Type de coloration
- FAM, LIZ, NED, PET, VIC
- Code à barre
- non
- Compatibilité de plateforme
- 310 Genetic Analyzer, 3100-Avant Genetic Analyzer, 3130xl Genetic Analyzer, 3500 Genetic Analyzer, 3500xL Genetic Analyzer, 3730 DNA Analyzer, GeneAmp 9600, GeneAmp 9700
- Marque
- APPLIED BIOSYSTEMS
- Référence fabricant
- 4427368
- Fournisseur
- Life Technologies
- Référence distributeur
- 4427368
- Délai de péremption à la date de livraison
- 10 mois
- Type de produit
- kit
- Soumis à carboglace
- oui
- Température de transport
- Dry Ice
- Vendu par
- 200 réactions
- Nomenclature Nacres
- NA.55
- Nomenclature CEA
- SGP01
- Nomenclature IRSN
- 273
- Nomenclature INSERM
- NA.NA55
- Nomenclature CNRS
- NA55
- Nomenclature CHU
- 18.551
- Soumis à réglementation
- For In Vitro Diagnostic Use.
- Nomenclature DGOS
- LD10AOOO
- Reprise en cas d’erreur client
- non
- Type d’application
- diagnostic
- Lieu de stockage
- Bleiswijk (Pays-Bas)
- Lieu de fabrication
- Grande Bretagne
- Quantité
- N/A
- Type d'échantillon
- prélèvement légal
- Domaine de recherche
- diagnostic génétique
- Certification
- RUO